Most industrial ethylene oxide (EO) is produced by direct oxidation of ethylene over a silver catalyst.

There are three key measurement locations for process control, where the following parameters are monitored over the following typical ranges:

Reactor Inlet
O2 0-12%
C2H4 0-40%

Reactor Outlet
O2 0-12%
CO2 0-5%
C2H4 0-40%

CO2 Absorber
CO2 0-30%
C2H4 0-40%